Product Description
Arc Resistance Tester NDH-15K
NDH-15KImmerse yourself in the unparalleled realm of precision testing with our Arc Resistance Test System! Meticulously engineered, this top-tier system is designed to meet the exacting demands of electrical insulation material examination. As a pinnacle of excellence, it stands as a testament to our commitment to innovation and quality in testing equipment.,it's sthe quintessential choice for analyzing electrical insulation materials. It expertly evaluates a wide range of materials including plastics, films, resins, mica, ceramics, glass, insulating paints, and a multitude of other insulating materials. This ensures a superior arc resistance evaluation. Moreover, it is an indispensable asset for product testing and for exploring the electrical properties of innovative materials, truly a must-have for any serious testing laboratory.
Application area
PCB
Photovoltaic Film Materials
PTFE, ABS, Nylon, and Other Plastics
Film Material
Insulating Paint
Mica Materials
Ceramic, Glass Fiber, etc.
Detailed Photos
Functional features
Our cutting-edge insulation materials exhibit remarkable resistance to degradation caused by high-voltage arc activity. Typically, a standard arc flame initiates carbonization on the material's surface, transforming it until it becomes conductive. The duration for the arc to extinguish is precisely measured in seconds. Utilizing two tungsten electrodes placed at a specific interval on the sample plate,the arc begins intermittently, progressively shortening until it forms a continuous arc as the current increases. The material faces increasingly severe arc conditions, leading to eventual failure. The resistance to arcs is essential for insulating materials in high-voltage switches or low-voltage high-current switches, regularly encountering arcs during usage. Only materials demonstrating exceptional arc resistance are suitable.
In the realm of electrical and electronic devices, insulating materials exposed to high-voltage, low-current arc discharges exhibit distinctive surface damage variations near the arc. These discharges cause localized thermal and chemical deterioration and corrosion, eventually creating a conductive pathway on the material. Once a conductive channel forms, the material is deemed to have failed the test.
The Arc Resistance Tester is aligned with prestigious standards such as GB1411, IEC61621, ASTMC495, and UL746A, making it an essential instrument for conducting simulated safety testing procedures. It ensures your testing processes adhere to the highest international benchmarks.
Engineered with precision to meet rigorous standard requirements, the arc resistance tester boasts comprehensive electrical schematics and high-precision electrodes. This ensures accurate and reliable testing outcomes every time.
Product Parameters
Arc on/off time error |
All program segments are superior±1ms |
Voltage regulator capacity |
1kVA |
Rated test voltage |
12.5kV |
Maximum test voltage |
15kV |
Electrode pressure on sample |
(0.5±0.05)N |
Electrode material |
Tungsten bars |
Test voltage accuracy |
<1.5% |
Current measurement accuracy |
<1.5% |
Distance between electrodes |
(6.35±0.1)mm(IEC) (6.0±0.1)mm(ASTM) |
Ambient temperature |
(23±2)ºC |
Ambient humidity |
(50±5)% |
Power supply |
220V±5% 50Hz 10A |
Program segment |
Arc current mA |
Arc on&off time /s |
Duration of each program segment/s |
Total test time/s |
IEC 61621 |
ASTM D495 |
1 |
10 |
1/8son 7/8s off |
1/8son 7/8s off |
60 |
60 |
2 |
10 |
1/4s on 3/4s off |
1/4s on 3/4s off |
60 |
120 |
3 |
10 |
1/4s on 1/4s off |
1/4s on 1/4s off |
60 |
180 |
4 |
10 |
Continuous power on |
60 |
240 |
5 |
20 |
Continuous power on |
60 |
300 |
6 |
30 |
Continuous power on |
60 |
360 |
7 |
40 |
Continuous power on |
60 |
420 |
Note:Ensure all instruments and equipment are properly grounded, maintaining grounding resistance at ≤4Ω to guarantee safety and optimal performance. ,The Supply and Demand parties agree that the supplier will provide technical specifications while the demander is responsible for establishing their own grounding system. This synergy ensures a seamless and effective testing setup.
Exhibition photos