Computer Controlled Voltage Breakdown Tester

Product Details
Customization: Available
Shipping & Policy
Shipping Cost: Contact the supplier about freight and estimated delivery time.
Payment Methods:
visa mastercard discover JCB diners club american express T/T
PIX SPEI OXXO PSE OZOW
  Support payments in USD
Secure payments: Every payment you make on Made-in-China.com is protected by the platform.
Refund policy: Claim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secured Trading Service
Gold Member Since 2024

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Self-branded
The supplier has 2 Self-brands, check the Audit Report for more information
Patents Awarded
The supplier had awarded 8 patents, you can check the Audit Report for more information
National Award received
This supplier had received national award, you can check the Audit Report for more information
to see all verified strength labels (24)
  • Computer Controlled Voltage Breakdown Tester
  • Computer Controlled Voltage Breakdown Tester
Find Similar Products

Basic Info.

Model NO.
GJW-100E

Packaging & Delivery

Package Size
17.40cm * 12.90cm * 18.20cm
Package Gross Weight
420.000kg

Product Description

I. Manufacturing and inspection standards of products 
1.GB/T1408.1-2006<Electrical strength of insulating materials -Test methods - Part 1:Tests at power frequencies>
2.GB/T1408.2-2016<Insulating materials -Test methods for electric strength -Part 2:Additional requirements for tests using direct voltage>
3.JJG 795-2016 <Withstanding Voltage Testers>
II. Applicable test method standards

1.GB/T1695-2005< Rubber,vulcanized - Determination of electrical breakdown strength and voltage resistant at commercial power frequency>
2.GB/T3333-1999<Cable paper- Determination of electrical strength at power frequence>
3.GB/T12913-2008<Capacitor tissue paper>
4.ASTM D149<Test method for dielectric breakdown voltage and dielectric strength of solid electrical insulating materials at commercial power frequencies>
III.Scope of application
It is mainly applicable to the test of breakdown strength and withstand voltage time of solid insulating materials such as wire sleeve, resin and adhesive, impregnated fiber products, mica and its products, plastics, film composite products, ceramics and glass under power frequency voltage or DC voltage; The instrument is controlled by computer, which can quickly and accurately collect and process various data in the test process, and can access, display and print.
 IV. Structural principle and characteristics
The equipment is mainly composed of:touch screen control system,Bluetooth communication system,Booster system (high voltage transformer),measurement system,discharge system,electrode,oil tank,electrode positioning stand,computer data processing system,software,etc.
V. Touch screen control system, computer system and software package
Touch screen control system is the latest developed by our company, with powerful function, simple operation and intuitive display. The instrument adopts touch screen control and completes the power frequency voltage breakdown and power frequency withstand voltage test of insulating medium through human-computer conversion.
Simple parameter can be set through the touch screen to complete all tests and the test result can be exported via USB, but there will be no curve of the test process. If you need a graph, you need to connect a computer.
  1. During the test, the test curve can be drawn dynamically. The test curve can be superimposed and compared with a variety of colors and locally enlarged. Any section of the curve can be analyzed by regional amplification;
  2. The test data can be edited and modified, which is flexible and applicable;
  3. Test conditions and test results data can be stored automatically;
  4. The test report format is flexible and adaptable to the different needs of different users;
  5. The validity of curve data in a group of tests can be manually selected;
  6. Test result data can be imported into Excel and Word for editing;
  7. The overcurrent protection device has sufficient sensitivity to ensure that the power supply is cut off within 0.1s when sample breaks down;
  8. Durability of instrument operation: the instrument can be operated continuously without regular shutdown to protect the instrument;
  9. Automatic voltage stabilization function during voltage withstand test (not affected by voltage grid voltage fluctuation).
  10. The testing software is the latest developed by our company,with powerful functions,simple operation and intuitive display.
    The instrument adopts computer control and completes the power frequency voltage breakdown and power frequency withstand voltage test of insulating medium through human-computer conversion. This instrument is the first of its kind and the patented product of our company, patent number: ZL 2017 2 1731210.3
VI.Safety instructions for high voltage breakdown equipment:
  1. Separate protective ground wire should be installed for the equipment. The protective grounding wire is mainly used to reduce the strong electromagnetic interference to the surrounding when the sample breaks down;It can also prevent the computer from getting out of control.
  2. DC test discharge alarm function:After the equipment has completed the DC test, the equipment will automatically alarm when the test door is opened, and the alarm will automatically cancel after the discharge device is used to discharge.(Note: It is dangerous not to discharge after DC test, the electrode cannot be taken directly. The alarm device will remind the operator to discharge so as not to cause personal injury).
  3. The test discharge device, integrated with the host, improve the function of previously equipped with a separate discharge pole.
  4. Safety protection:
a.Door interlock protection
b.Over-voltage and over-current protection
c.High voltage warning light
d.Emergency stop button
e.Discharge alarm
f.Leakage protection switch

VII.Functional features:
  1. Operated and controlled by the touch screen and control panel of the device itself.If curve analysis is not required, it can not be equipped with a computer.
  2. If curve analysis is required, a computer can be equipped to only perform data and curve recording functions, without controlling the equipment, avoid the need for testers to alternate between the computer and equipment, make it more user-friendly.
  3. The equipment has the function of test parameter memory.The same test conditions do not need to be set for each test, and even if the power is cut off, the last test setting parameters will still be remembered.
  4. The test interface is simple and clear, and is equipped with schematic curve description, different parameters, different curve trends, easy to understand.
  5. The control panel is simple,with clear functional labeling and easy operation.
  6. It can record and display 10 test records simultaneously, facilitating comparative analysis of test data, and any set of data that isn't ideal can be discarded at any time.
  7. Added USB download function,which can download the test records in the device directly to the USB.
  8. If equipped with a computer, a detailed test report can be generated, including each group of specific information,multiple groups of comprehensive information and curves.
  9. The equipment testing interface adopts a dashboard and digital display mode that is both simultaneously and real-time, making it more convenient to observe the testing process.
  10. The equipment has safety warning prompt, the test cannot start without closing the test chamber door, and a warning will pop up and the warning will pop up when the full degree (i.e. no output from the high-voltage transformer), and the test will automatically end if the door is opened during the test.
  11. Using Bluetooth data transmission to solve the problem of being blocked by isolation walls, remote operation is safe and reliable.
  12. The equipment is equipped with three color alarm light. When the green light is on, it indicates that the chamber door is closed well and the test can start; when the yellow light is on, it indicates that the chamber door is open and the sample can be replaced; when the red light is on, it indicates that the high voltage is higher than 0.5kV and the chamber door shouldn't be opened at this time. The warning light will flash and sound an alarm during the discharge process after the DC test is completed.(Green light:The chamber door is closed properly; Yellow light: Be careful when opening the door; Red light: There's high voltage)






 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now